Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75.5mm
Voltage typeAC
Rated voltage240V
Rated current16A
Frequency50 Hz
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Rated fault current0.3A
Number of protected poles1
Connectable conductor cross section solid-core1 - 25mm²
Disconnection characteristicUndelayed
Release characteristicC
Concurrently switching neutral conductorYes
Current limiting class3
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Pollution degree2
Leakage current typeA
Surge current capacity0.25kA
Over voltage category3
Rated short-circuit breaking capacity according to EN 610096kA
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated insulation voltage Ui500V
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C16/1N/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75.5mm

Voltage type

AC

Rated voltage

240V

Rated current

16A

Frequency

50 Hz

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Rated fault current

0.3A

Number of protected poles

1

Connectable conductor cross section solid-core

1 .. 25mm²

Disconnection characteristic

Undelayed

Release characteristic

C

Concurrently switching neutral conductor

Current limiting class

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Leakage current type

A

Surge current capacity

0.25kA

Over voltage category

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated insulation voltage Ui

500V

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Width in number of modular spacings

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.