Technical specifications

Rated voltage240V
Rated insulation voltage Ui500V
Built-in depth75.5mm
Release characteristicC
Rated current2A
Frequency50 Hz
Leakage current typeAC
Surge current capacity0.25kA
Concurrently switching neutral conductorYes
Number of protected poles1
Width in number of modular spacings2
Current limiting class3
Over voltage category3
Degree of protection (IP)IP20
Rated fault current0.03A
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Voltage typeAC
With interlocking deviceNo
Flush-mounted installationNo
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C2/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Rated insulation voltage Ui

500V

Built-in depth

75.5mm

Release characteristic

C

Rated current

2A

Frequency

50 Hz

Leakage current type

AC

Surge current capacity

0.25kA

Concurrently switching neutral conductor

Number of protected poles

1

Width in number of modular spacings

2

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP20

Rated fault current

0.03A

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Voltage type

AC

With interlocking device

Flush-mounted installation

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA