  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75.5mm
Voltage typeAC
Rated voltage240V
Release characteristicC
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Pollution degree2
Current limiting class3
Frequency50 Hz
Over voltage category3
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to EN 610096kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles1
Rated current2A
Rated fault current0.3A
Leakage current typeAC
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C2/1N/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75.5mm

Voltage type

AC

Rated voltage

240V

Release characteristic

C

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Pollution degree

2

Current limiting class

3

Frequency

50 Hz

Over voltage category

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

1

Rated current

2A

Rated fault current

0.3A

Leakage current type

AC

Number of poles (total)

2