Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category3
Surge current capacity0.25kA
Pollution degree2
Rated insulation voltage Ui500V
Voltage typeAC
Current limiting class3
Rated voltage240V
Built-in depth75.5mm
Release characteristicC
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles2
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Ambient temperature during operating-25 - 40°C
Frequency50 Hz
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated current20A
Rated fault current0.03A
Leakage current typeAC
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C20/2/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category

3

Surge current capacity

0.25kA

Pollution degree

2

Rated insulation voltage Ui

500V

Voltage type

AC

Current limiting class

3

Rated voltage

240V

Built-in depth

75.5mm

Release characteristic

C

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Ambient temperature during operating

-25 .. 40°C

Frequency

50 Hz

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

20A

Rated fault current

0.03A

Leakage current type

AC

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.