Built-in depth75.5mm
Rated voltage240V
Voltage typeAC
Rated fault current0.1A
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated current25A
Release characteristicC
Leakage current typeAC
Current limiting class3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Over voltage category3
Frequency50 Hz
With interlocking deviceNo
Pollution degree2
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Number of protected poles1
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)2
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C25/1N/01

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75.5mm

Rated voltage

240V

Voltage type

AC

Rated fault current

0.1A

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated current

25A

Release characteristic

C

Leakage current type

AC

Current limiting class

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

3

Frequency

50 Hz

With interlocking device

Pollution degree

2

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Number of protected poles

1

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

2

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.