Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Width in number of modular spacings2
Release characteristicC
With interlocking deviceNo
Current limiting class3
Pollution degree2
Frequency50 Hz
Connectable conductor cross section multi-wired1 - 25mm²
Over voltage category3
Rated current40A
Degree of protection (IP)IP20
Leakage current typeA
Ambient temperature during operating-25 - 40°C
Rated insulation voltage Ui500V
Rated voltage240V
Built-in depth75.5mm
Number of poles (total)2
Surge current capacity0.25kA
Rated fault current0.1A
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles2
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C40/2/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Width in number of modular spacings

2

Release characteristic

C

With interlocking device

Current limiting class

3

Pollution degree

2

Frequency

50 Hz

Connectable conductor cross section multi-wired

1 .. 25mm²

Over voltage category

3

Rated current

40A

Degree of protection (IP)

IP20

Leakage current type

A

Ambient temperature during operating

-25 .. 40°C

Rated insulation voltage Ui

500V

Rated voltage

240V

Built-in depth

75.5mm

Number of poles (total)

2

Surge current capacity

0.25kA

Rated fault current

0.1A

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

2

Anti-nuisance tripping version

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA