Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Voltage typeAC
Built-in depth75.5mm
Over voltage category3
Rated fault current0.3A
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Leakage current typeA
Connectable conductor cross section multi-wired1 - 25mm²
Surge current capacity0.25kA
Rated voltage240V
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles2
Width in number of modular spacings2
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Release characteristicC
Concurrently switching neutral conductorNo
Frequency50 Hz
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Flush-mounted installationNo
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 610096kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C40/2/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Voltage type

AC

Built-in depth

75.5mm

Over voltage category

3

Rated fault current

0.3A

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Leakage current type

A

Connectable conductor cross section multi-wired

1 .. 25mm²

Surge current capacity

0.25kA

Rated voltage

240V

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

2

Width in number of modular spacings

2

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Release characteristic

C

Concurrently switching neutral conductor

Frequency

50 Hz

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Flush-mounted installation

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

6kA