Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category3
Leakage current typeAC
Surge current capacity0.25kA
Pollution degree2
Rated fault current0.03A
Rated insulation voltage Ui500V
Width in number of modular spacings2
Current limiting class3
Rated current16A
Voltage typeAC
Rated voltage240V
Release characteristicD
Built-in depth75.5mm
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
Frequency50 Hz
With interlocking deviceNo
Number of protected poles1
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 40°C
Suitable for flush-mounted installationNo
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-D16/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category

3

Leakage current type

AC

Surge current capacity

0.25kA

Pollution degree

2

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Current limiting class

3

Rated current

16A

Voltage type

AC

Rated voltage

240V

Release characteristic

D

Built-in depth

75.5mm

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50 Hz

With interlocking device

Number of protected poles

1

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Suitable for flush-mounted installation

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.