Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristicD
Rated insulation voltage Ui500V
Built-in depth75.5mm
Surge current capacity0.25kA
Current limiting class3
Voltage typeAC
Rated voltage240V
Frequency50 Hz
Number of protected poles1
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings2
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated current2A
Rated fault current0.01A
Leakage current typeAC
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-D2/1N/001

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Rated insulation voltage Ui

500V

Built-in depth

75.5mm

Surge current capacity

0.25kA

Current limiting class

3

Voltage type

AC

Rated voltage

240V

Frequency

50 Hz

Number of protected poles

1

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

2

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

2A

Rated fault current

0.01A

Leakage current type

AC

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.