Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage415V
Rated insulation voltage Ui500V
Rated current6A
Built-in depth75.5mm
Release characteristicD
Voltage typeAC
Width in number of modular spacings4
Current limiting class3
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Surge current capacity0.25kA
Number of poles (total)4
Over voltage category3
Frequency50 Hz
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Number of protected poles4
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Leakage current typeA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-D6/3N/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated current

6A

Built-in depth

75.5mm

Release characteristic

D

Voltage type

AC

Width in number of modular spacings

4

Current limiting class

3

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Surge current capacity

0.25kA

Number of poles (total)

4

Over voltage category

3

Frequency

50 Hz

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Number of protected poles

4

Anti-nuisance tripping version

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Leakage current type

A

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.