Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current0.1A
Voltage typeAC
Rated current10A
Built-in depth75.5mm
Rated voltage240V
Release characteristicB
Leakage current typeA
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Current limiting class3
With interlocking deviceNo
Frequency50 Hz
Pollution degree2
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Over voltage category3
Number of protected poles1
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Concurrently switching neutral conductorYes
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to IEC 60947-215kA
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B10/1N/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current

0.1A

Voltage type

AC

Rated current

10A

Built-in depth

75.5mm

Rated voltage

240V

Release characteristic

B

Leakage current type

A

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Current limiting class

3

With interlocking device

Frequency

50 Hz

Pollution degree

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Over voltage category

3

Number of protected poles

1

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Flush-mounted installation

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.