Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Pollution degree2
Built-in depth75.5mm
Release characteristicB
Rated current13A
Rated fault current0.03A
Degree of protection (IP)IP20
Surge current capacity3kA
Rated insulation voltage Ui500V
Leakage current typeAC
Frequency50 Hz
Rated voltage240V
Width in number of modular spacings2
Over voltage category3
Current limiting class3
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-215kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Disconnection characteristicShort-time delayed
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
With interlocking deviceNo
Anti-nuisance tripping versionYes
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B13/1N/003-G

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Pollution degree

2

Built-in depth

75.5mm

Release characteristic

B

Rated current

13A

Rated fault current

0.03A

Degree of protection (IP)

IP20

Surge current capacity

3kA

Rated insulation voltage Ui

500V

Leakage current type

AC

Frequency

50 Hz

Rated voltage

240V

Width in number of modular spacings

2

Over voltage category

3

Current limiting class

3

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Short-time delayed

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

With interlocking device

Anti-nuisance tripping version

Flush-mounted installation

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.