Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)2
Rated insulation voltage Ui500V
Number of protected poles1
Rated current13A
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Over voltage category3
With interlocking deviceNo
Pollution degree2
Frequency50 Hz
Release characteristicB
Rated voltage240V
Voltage typeAC
Ambient temperature during operating-25 - 40°C
Rated fault current0.1A
Surge current capacity0.25kA
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Built-in depth75.5mm
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B13/1N/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

500V

Number of protected poles

1

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Over voltage category

3

With interlocking device

Pollution degree

2

Frequency

50 Hz

Release characteristic

B

Rated voltage

240V

Voltage type

AC

Ambient temperature during operating

-25 .. 40°C

Rated fault current

0.1A

Surge current capacity

0.25kA

Concurrently switching neutral conductor

Width in number of modular spacings

2

Anti-nuisance tripping version

Flush-mounted installation

Built-in depth

75.5mm

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Related products