Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage240V
Built-in depth75.5mm
Rated current13A
Release characteristicB
Rated insulation voltage Ui500V
Rated fault current0.3A
Frequency50 Hz
Leakage current typeAC
Surge current capacity0.25kA
Connectable conductor cross section solid-core1 - 25mm²
Over voltage category3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-215kA
Width in number of modular spacings2
Number of protected poles1
Current limiting class3
Pollution degree2
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B13/1N/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

240V

Built-in depth

75.5mm

Rated current

13A

Release characteristic

B

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Frequency

50 Hz

Leakage current type

AC

Surge current capacity

0.25kA

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Width in number of modular spacings

2

Number of protected poles

1

Current limiting class

3

Pollution degree

2

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated impulse withstand voltage Uimp

4kV

Related products