Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current typeA
Pollution degree2
Built-in depth75.5mm
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Over voltage category3
Release characteristicB
Voltage typeAC
Rated current13A
Width in number of modular spacings2
Rated fault current0.1A
Rated voltage240V
Current limiting class3
Frequency50 Hz
Number of protected poles2
Degree of protection (IP)IP20
Disconnection characteristicUndelayed
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B13/2/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current type

A

Pollution degree

2

Built-in depth

75.5mm

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Over voltage category

3

Release characteristic

B

Voltage type

AC

Rated current

13A

Width in number of modular spacings

2

Rated fault current

0.1A

Rated voltage

240V

Current limiting class

3

Frequency

50 Hz

Number of protected poles

2

Degree of protection (IP)

IP20

Disconnection characteristic

Undelayed

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Anti-nuisance tripping version

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Related products