Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles2
Number of poles (total)2
Rated voltage240V
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Rated current13A
Rated fault current0.1A
Leakage current typeA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to IEC 60947-20kA
Voltage typeAC
Release characteristicB
Frequency50 Hz
With interlocking deviceNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicShort-time delayed
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to EN 6100910kA
Concurrently switching neutral conductorNo
Pollution degree2
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Built-in depth75.5mm
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings2
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B13/2/01-LIA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated voltage

240V

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Rated current

13A

Rated fault current

0.1A

Leakage current type

A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Voltage type

AC

Release characteristic

B

Frequency

50 Hz

With interlocking device

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Short-time delayed

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Built-in depth

75.5mm

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20