Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current0.01A
Voltage typeAC
Width in number of modular spacings2
Rated insulation voltage Ui500V
Rated voltage240V
Surge current capacity0.25kA
Built-in depth75.5mm
Rated current16A
Release characteristicB
Leakage current typeAC
Pollution degree2
Over voltage category3
Current limiting class3
Number of protected poles1
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
With interlocking deviceNo
Frequency50 Hz

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B16/1N/001

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current

0.01A

Voltage type

AC

Width in number of modular spacings

2

Rated insulation voltage Ui

500V

Rated voltage

240V

Surge current capacity

0.25kA

Built-in depth

75.5mm

Rated current

16A

Release characteristic

B

Leakage current type

AC

Pollution degree

2

Over voltage category

3

Current limiting class

3

Number of protected poles

1

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

With interlocking device

Frequency

50 Hz

Related products