Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current16A
Release characteristicB
Voltage typeAC
Rated voltage240V
Leakage current typeA
Current limiting class3
Built-in depth75.5mm
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated fault current0.03A
Over voltage category3
Number of protected poles1
Pollution degree2
Width in number of modular spacings2
Degree of protection (IP)IP20
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
With interlocking deviceNo
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B16/1N/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

16A

Release characteristic

B

Voltage type

AC

Rated voltage

240V

Leakage current type

A

Current limiting class

3

Built-in depth

75.5mm

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Over voltage category

3

Number of protected poles

1

Pollution degree

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

With interlocking device

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.