Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Over voltage category3
Surge current capacity0.25kA
Current limiting class3
Rated voltage240V
Pollution degree2
Width in number of modular spacings2
Release characteristicB
Rated insulation voltage Ui500V
Rated current16A
Built-in depth75.5mm
Rated fault current0.03A
Leakage current typeAC
Degree of protection (IP)IP20
Frequency50 Hz
Number of poles (total)2
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core1 - 25mm²
Disconnection characteristicUndelayed
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B16/2/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Over voltage category

3

Surge current capacity

0.25kA

Current limiting class

3

Rated voltage

240V

Pollution degree

2

Width in number of modular spacings

2

Release characteristic

B

Rated insulation voltage Ui

500V

Rated current

16A

Built-in depth

75.5mm

Rated fault current

0.03A

Leakage current type

AC

Degree of protection (IP)

IP20

Frequency

50 Hz

Number of poles (total)

2

Flush-mounted installation

Concurrently switching neutral conductor

Anti-nuisance tripping version

Connectable conductor cross section solid-core

1 .. 25mm²

Disconnection characteristic

Undelayed

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.