Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth75.5mm
Rated current20A
Rated voltage240V
Rated insulation voltage Ui500V
Release characteristicB
Rated fault current0.1A
Number of protected poles2
Over voltage category3
Pollution degree2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Leakage current typeA
Current limiting class3
Number of poles (total)2
Surge current capacity0.25kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Disconnection characteristicShort-time delayed
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B20/2/01-LIA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

75.5mm

Rated current

20A

Rated voltage

240V

Rated insulation voltage Ui

500V

Release characteristic

B

Rated fault current

0.1A

Number of protected poles

2

Over voltage category

3

Pollution degree

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

2

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Leakage current type

A

Current limiting class

3

Number of poles (total)

2

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Disconnection characteristic

Short-time delayed

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Related products