Rated voltage240V
Release characteristicB
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Current limiting class3
Over voltage category3
Built-in depth75.5mm
Voltage typeAC
Pollution degree2
Width in number of modular spacings2
Number of protected poles1
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Frequency50 Hz
Rated short-circuit breaking capacity according to EN 6100910kA
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Rated current25A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B25/1N/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Release characteristic

B

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Current limiting class

3

Over voltage category

3

Built-in depth

75.5mm

Voltage type

AC

Pollution degree

2

Width in number of modular spacings

2

Number of protected poles

1

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Frequency

50 Hz

Rated short-circuit breaking capacity according to EN 61009

10kA

Flush-mounted installation

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Rated current

25A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

2