Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage240V
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated current10A
Release characteristicC
Built-in depth75.5mm
Rated fault current0.03A
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings2
Rated insulation voltage Ui500V
Number of protected poles2
Concurrently switching neutral conductorNo
Leakage current typeA
Connectable conductor cross section solid-core1 - 25mm²
Frequency50 Hz
Surge current capacity0.25kA
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C10/2/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

240V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated current

10A

Release characteristic

C

Built-in depth

75.5mm

Rated fault current

0.03A

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

2

Rated insulation voltage Ui

500V

Number of protected poles

2

Concurrently switching neutral conductor

Leakage current type

A

Connectable conductor cross section solid-core

1 .. 25mm²

Frequency

50 Hz

Surge current capacity

0.25kA

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Flush-mounted installation

Related products