  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles3
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated voltage415V
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to IEC 60947-215kA
Current limiting class3
Rated current10A
Leakage current typeA
Rated fault current0.03A
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Frequency50 Hz
Surge current capacity0.25kA
Voltage typeAC
Release characteristicC
Concurrently switching neutral conductorNo
Pollution degree2
Ambient temperature during operating-25 - 40°C
Over voltage category3
With interlocking deviceNo
Width in number of modular spacings4
Built-in depth75.5mm
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C10/3/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

3

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Current limiting class

3

Rated current

10A

Leakage current type

A

Rated fault current

0.03A

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Frequency

50 Hz

Surge current capacity

0.25kA

Voltage type

AC

Release characteristic

C

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Over voltage category

3

With interlocking device

Width in number of modular spacings

4

Built-in depth

75.5mm

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version