Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category3
Rated fault current0.3A
Width in number of modular spacings2
Rated current13A
Release characteristicC
Rated voltage240V
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Current limiting class3
Frequency50 Hz
Pollution degree2
Voltage typeAC
Leakage current typeAC
Built-in depth75.5mm
Number of protected poles2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Anti-nuisance tripping versionNo
With interlocking deviceNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C13/2/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Over voltage category

3

Rated fault current

0.3A

Width in number of modular spacings

2

Rated current

13A

Release characteristic

C

Rated voltage

240V

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Current limiting class

3

Frequency

50 Hz

Pollution degree

2

Voltage type

AC

Leakage current type

AC

Built-in depth

75.5mm

Number of protected poles

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Anti-nuisance tripping version

With interlocking device

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Related products