Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Voltage typeAC
Built-in depth75.5mm
Release characteristicC
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated fault current0.3A
Over voltage category3
Rated voltage240V
Leakage current typeAC
Rated current16A
Pollution degree2
With interlocking deviceNo
Frequency50 Hz
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of poles (total)2
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Connectable conductor cross section solid-core1 - 25mm²
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Number of protected poles1
Rated short-circuit breaking capacity according to EN 6100910kA
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C16/1N/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Voltage type

AC

Built-in depth

75.5mm

Release characteristic

C

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Over voltage category

3

Rated voltage

240V

Leakage current type

AC

Rated current

16A

Pollution degree

2

With interlocking device

Frequency

50 Hz

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of poles (total)

2

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

1 .. 25mm²

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Number of protected poles

1

Rated short-circuit breaking capacity according to EN 61009

10kA