Technical specifications

Mounting methodDIN rail
Built-in depth75.5mm
Rated fault current0.03A
Rated voltage240V
Rated current2A
Release characteristicC
Rated insulation voltage Ui500V
Voltage typeAC
Concurrently switching neutral conductorYes
Pollution degree2
Over voltage category3
Surge current capacity0.25kA
Current limiting class3
Leakage current typeAC
Degree of protection (IP)IP20
Width in number of modular spacings2
Frequency50 Hz
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C2/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Mounting method

DIN rail

Built-in depth

75.5mm

Rated fault current

0.03A

Rated voltage

240V

Rated current

2A

Release characteristic

C

Rated insulation voltage Ui

500V

Voltage type

AC

Concurrently switching neutral conductor

Pollution degree

2

Over voltage category

3

Surge current capacity

0.25kA

Current limiting class

3

Leakage current type

AC

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Frequency

50 Hz

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Related products