Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Over voltage category3
Ambient temperature during operating-25 - 40°C
Built-in depth75.5mm
Release characteristicC
Rated fault current0.1A
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section solid-core1 - 25mm²
Current limiting class3
Rated voltage240V
Number of poles (total)2
Frequency50 Hz
Concurrently switching neutral conductorYes
Leakage current typeAC
Rated insulation voltage Ui500V
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Rated current2A
With interlocking deviceNo
Number of protected poles1
Degree of protection (IP)IP20
Surge current capacity0.25kA
Pollution degree2
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C2/1N/01

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Built-in depth

75.5mm

Release characteristic

C

Rated fault current

0.1A

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

Current limiting class

3

Rated voltage

240V

Number of poles (total)

2

Frequency

50 Hz

Concurrently switching neutral conductor

Leakage current type

AC

Rated insulation voltage Ui

500V

Anti-nuisance tripping version

Flush-mounted installation

Rated current

2A

With interlocking device

Number of protected poles

1

Degree of protection (IP)

IP20

Surge current capacity

0.25kA

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.