Voltage typeAC
Built-in depth75.5mm
Rated voltage240V
Rated insulation voltage Ui500V
Release characteristicC
Number of protected poles2
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings2
Surge current capacity0.25kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Disconnection characteristicUndelayed
Over voltage category3
Pollution degree2
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Rated current20A
Rated fault current0.3A
Leakage current typeAC
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C20/2/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

75.5mm

Rated voltage

240V

Rated insulation voltage Ui

500V

Release characteristic

C

Number of protected poles

2

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Over voltage category

3

Pollution degree

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Rated current

20A

Rated fault current

0.3A

Leakage current type

AC

Number of poles (total)

2

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.