Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Voltage typeAC
Rated current20A
Built-in depth75.5mm
Rated voltage240V
Rated insulation voltage Ui500V
Leakage current typeA
Surge current capacity0.25kA
Rated fault current0.3A
Over voltage category3
Pollution degree2
Degree of protection (IP)IP20
Number of protected poles2
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Current limiting class3
Frequency50 Hz
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C20/2/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Voltage type

AC

Rated current

20A

Built-in depth

75.5mm

Rated voltage

240V

Rated insulation voltage Ui

500V

Leakage current type

A

Surge current capacity

0.25kA

Rated fault current

0.3A

Over voltage category

3

Pollution degree

2

Degree of protection (IP)

IP20

Number of protected poles

2

Width in number of modular spacings

2

Concurrently switching neutral conductor

Current limiting class

3

Frequency

50 Hz

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.