Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Rated fault current0.03A
Built-in depth75.5mm
Leakage current typeA
Rated voltage240V
Surge current capacity0.25kA
Voltage typeAC
Rated current25A
Current limiting class3
Rated insulation voltage Ui500V
Over voltage category3
Pollution degree2
Concurrently switching neutral conductorNo
Number of protected poles2
Degree of protection (IP)IP20
Width in number of modular spacings2
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C25/2/003-LIA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Rated fault current

0.03A

Built-in depth

75.5mm

Leakage current type

A

Rated voltage

240V

Surge current capacity

0.25kA

Voltage type

AC

Rated current

25A

Current limiting class

3

Rated insulation voltage Ui

500V

Over voltage category

3

Pollution degree

2

Concurrently switching neutral conductor

Number of protected poles

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Flush-mounted installation

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.