  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated insulation voltage Ui500V
Built-in depth75.5mm
Rated voltage240V
Rated current25A
Release characteristicC
Frequency50 Hz
Width in number of modular spacings2
Rated fault current0.1A
Over voltage category3
Pollution degree2
Number of poles (total)2
Anti-nuisance tripping versionNo
Surge current capacity0.25kA
Leakage current typeA
Current limiting class3
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of protected poles2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C25/2/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

500V

Built-in depth

75.5mm

Rated voltage

240V

Rated current

25A

Release characteristic

C

Frequency

50 Hz

Width in number of modular spacings

2

Rated fault current

0.1A

Over voltage category

3

Pollution degree

2

Number of poles (total)

2

Anti-nuisance tripping version

Surge current capacity

0.25kA

Leakage current type

A

Current limiting class

3

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of protected poles

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed