Technical specifications

Release characteristicC
Built-in depth75.5mm
Voltage typeAC
Rated current25A
Rated voltage240V
Frequency50 Hz
Leakage current typeA
Rated fault current0.3A
Pollution degree2
Width in number of modular spacings2
Rated insulation voltage Ui500V
Current limiting class3
Over voltage category3
Number of protected poles2
Surge current capacity0.25kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
With interlocking deviceNo
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C25/2/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Built-in depth

75.5mm

Voltage type

AC

Rated current

25A

Rated voltage

240V

Frequency

50 Hz

Leakage current type

A

Rated fault current

0.3A

Pollution degree

2

Width in number of modular spacings

2

Rated insulation voltage Ui

500V

Current limiting class

3

Over voltage category

3

Number of protected poles

2

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

With interlocking device

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Related products