Technical specifications

Voltage typeAC
Built-in depth75.5mm
Rated voltage240V
Rated current4A
Current limiting class3
Leakage current typeA
Release characteristicC
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Width in number of modular spacings2
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of protected poles1
Rated fault current0.3A
Frequency50 Hz
Concurrently switching neutral conductorYes
With interlocking deviceNo
Over voltage category3
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C4/1N/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

75.5mm

Rated voltage

240V

Rated current

4A

Current limiting class

3

Leakage current type

A

Release characteristic

C

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of protected poles

1

Rated fault current

0.3A

Frequency

50 Hz

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.