Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current6A
Built-in depth75.5mm
Voltage typeAC
Number of protected poles1
Frequency50 Hz
Rated fault current0.03A
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Pollution degree2
Release characteristicC
Over voltage category3
Leakage current typeAC
Rated voltage240V
Width in number of modular spacings2
Current limiting class3
Surge current capacity0.25kA
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-C6/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

6A

Built-in depth

75.5mm

Voltage type

AC

Number of protected poles

1

Frequency

50 Hz

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Pollution degree

2

Release characteristic

C

Over voltage category

3

Leakage current type

AC

Rated voltage

240V

Width in number of modular spacings

2

Current limiting class

3

Surge current capacity

0.25kA

Concurrently switching neutral conductor

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.