Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current typeAC
Voltage typeAC
Rated voltage240V
Rated current13A
Rated insulation voltage Ui500V
Release characteristicD
Rated fault current0.03A
Built-in depth75.5mm
Surge current capacity0.25kA
Over voltage category3
Current limiting class3
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Frequency50 Hz
With interlocking deviceNo
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of protected poles1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D13/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current type

AC

Voltage type

AC

Rated voltage

240V

Rated current

13A

Rated insulation voltage Ui

500V

Release characteristic

D

Rated fault current

0.03A

Built-in depth

75.5mm

Surge current capacity

0.25kA

Over voltage category

3

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Concurrently switching neutral conductor

Frequency

50 Hz

With interlocking device

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of protected poles

1

Related products