Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)2
Rated voltage240V
Rated insulation voltage Ui500V
Rated current13A
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-215kA
Current limiting class3
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Leakage current typeA
Rated short-circuit breaking capacity according to EN 6100910kA
Frequency50 Hz
Surge current capacity0.25kA
Voltage typeAC
Release characteristicD
Concurrently switching neutral conductorYes
Rated fault current0.03A
Pollution degree2
With interlocking deviceNo
Over voltage category3
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Built-in depth75.5mm
Width in number of modular spacings2
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Anti-nuisance tripping versionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D13/1N/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated current

13A

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Current limiting class

3

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Leakage current type

A

Rated short-circuit breaking capacity according to EN 61009

10kA

Frequency

50 Hz

Surge current capacity

0.25kA

Voltage type

AC

Release characteristic

D

Concurrently switching neutral conductor

Rated fault current

0.03A

Pollution degree

2

With interlocking device

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Built-in depth

75.5mm

Width in number of modular spacings

2

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Anti-nuisance tripping version

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.