Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles3
Number of poles (total)3
Rated voltage415V
Rated fault current0.1A
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to IEC 60947-215kA
Disconnection characteristicUndelayed
Rated current13A
Frequency50 Hz
Surge current capacity0.25kA
With interlocking deviceNo
Voltage typeAC
Release characteristicD
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Pollution degree2
Width in number of modular spacings4
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Built-in depth75.5mm
Flush-mounted installationNo
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D13/3/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

3

Number of poles (total)

3

Rated voltage

415V

Rated fault current

0.1A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Disconnection characteristic

Undelayed

Rated current

13A

Frequency

50 Hz

Surge current capacity

0.25kA

With interlocking device

Voltage type

AC

Release characteristic

D

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Concurrently switching neutral conductor

Anti-nuisance tripping version

Pollution degree

2

Width in number of modular spacings

4

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Built-in depth

75.5mm

Flush-mounted installation

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.