  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth75.5mm
Rated insulation voltage Ui500V
Rated voltage240V
Release characteristicD
Surge current capacity0.25kA
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Over voltage category3
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Disconnection characteristicUndelayed
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
Current limiting class3
Number of protected poles1
Pollution degree2
Rated current16A
Rated fault current0.03A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D16/1N/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

75.5mm

Rated insulation voltage Ui

500V

Rated voltage

240V

Release characteristic

D

Surge current capacity

0.25kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

Current limiting class

3

Number of protected poles

1

Pollution degree

2

Rated current

16A

Rated fault current

0.03A

Leakage current type

A

Number of poles (total)

2

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.