Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current2A
Built-in depth75.5mm
Release characteristicD
Frequency50 Hz
Surge current capacity0.25kA
Rated voltage240V
Leakage current typeAC
Pollution degree2
Rated insulation voltage Ui500V
Over voltage category3
Width in number of modular spacings2
Rated fault current0.3A
Current limiting class3
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Number of poles (total)2
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
With interlocking deviceNo
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Number of protected poles1
Rated short-circuit breaking capacity according to EN 6100910kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D2/1N/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

2A

Built-in depth

75.5mm

Release characteristic

D

Frequency

50 Hz

Surge current capacity

0.25kA

Rated voltage

240V

Leakage current type

AC

Pollution degree

2

Rated insulation voltage Ui

500V

Over voltage category

3

Width in number of modular spacings

2

Rated fault current

0.3A

Current limiting class

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Number of poles (total)

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

With interlocking device

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

1

Rated short-circuit breaking capacity according to EN 61009

10kA