Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage240V
Release characteristicD
Rated fault current0.3A
Leakage current typeA
Built-in depth75.5mm
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated current20A
Voltage typeAC
Connectable conductor cross section multi-wired1 - 25mm²
Current limiting class3
Number of poles (total)2
Width in number of modular spacings2
Degree of protection (IP)IP20
With interlocking deviceNo
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Frequency50 Hz
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core1 - 25mm²
Over voltage category3
Concurrently switching neutral conductorYes
Number of protected poles1
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D20/1N/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Release characteristic

D

Rated fault current

0.3A

Leakage current type

A

Built-in depth

75.5mm

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated current

20A

Voltage type

AC

Connectable conductor cross section multi-wired

1 .. 25mm²

Current limiting class

3

Number of poles (total)

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

With interlocking device

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Frequency

50 Hz

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3

Concurrently switching neutral conductor

Number of protected poles

1

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.