Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Rated insulation voltage Ui500V
Rated voltage240V
Width in number of modular spacings2
Frequency50 Hz
Number of protected poles1
Release characteristicD
Pollution degree2
Degree of protection (IP)IP20
Voltage typeAC
Surge current capacity0.25kA
Built-in depth75.5mm
Over voltage category3
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Rated current4A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-D4/1N/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Rated insulation voltage Ui

500V

Rated voltage

240V

Width in number of modular spacings

2

Frequency

50 Hz

Number of protected poles

1

Release characteristic

D

Pollution degree

2

Degree of protection (IP)

IP20

Voltage type

AC

Surge current capacity

0.25kA

Built-in depth

75.5mm

Over voltage category

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Rated current

4A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

2

Related products