Details
- Sensors for automation technology
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
6A
Length of sensor
33.5mm
Output electronic
No
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.8A
Diameter sensor
0mm
Height of sensor
96mm
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
No
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Material housing
Plastic
Construction type housing
Cuboid
Type of interface
None
Type of control element
Plunger
Coating housing
Other
Number of safety auxiliary contacts
1
Type of electric connection
Cable entry metrical
With status indication
No
Alignment of the control element
Other
Number of contacts as normally closed contact
1
Forced opening
Yes
Explosion safety category for gas
None
Degree of protection (NEMA)
Other
Explosion safety category for dust
None
Suitable for safety functions
Yes
Ambient temperature during operating
-40 - 70°C
Degree of protection (IP)
IP65
LS-11-CC-ZB

Details
- Sensors for automation technology
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
6A
Length of sensor
33.5mm
Output electronic
Switching function
Slow-action switch
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.8A
Diameter sensor
0mm
Height of sensor
96mm
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at AC-15, 24 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
Number of contacts as normally open contact
1
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Material housing
Plastic
Construction type housing
Cuboid
Type of interface
None
Type of control element
Plunger
Coating housing
Other
Number of safety auxiliary contacts
1
Type of electric connection
Cable entry metrical
With status indication
Alignment of the control element
Other
Number of contacts as normally closed contact
1
Forced opening
Explosion safety category for gas
None
Degree of protection (NEMA)
Other
Explosion safety category for dust
None
Suitable for safety functions
Ambient temperature during operating
-40 .. 70°C
Degree of protection (IP)
IP65