Aleta.hr

Details

  • Sensors
  • End switch
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP65
Output electronicNo
Switching functionSlow-action switch
Rated operation current Ie at DC-13, 230 V0.3A
Type of control elementPlunger
Construction type housingCuboid
Forced openingYes
Type of interface for safety communicationNone
Type of interfaceNone
Rated operation current Ie at AC-15, 230 V6A
Suitable for safety functionsYes
With status indicationNo
Material housingPlastic
Explosion safety category for dustNone
Rated operation current Ie at AC-15, 125 V6A
Number of safety auxiliary contacts0
Explosion safety category for gasNone
Type of electric connectionCable entry metrical
Coating housingOther
Width sensor31mm
Rated operation current Ie at DC-13, 24 V3A
Rated operation current Ie at AC-15, 24 V6A
Rated operation current Ie at DC-13, 125 V0.8A
Alignment of the control elementRoller cam straight
Ambient temperature during operating-40 - 70°C
Height of sensor61mm
Length of sensor33.5mm
Diameter sensor0mm
Number of contacts as normally closed contact1
Switching function latchingNo
Number of contacts as change-over contact0
Degree of protection (NEMA)Other
Number of contacts as normally open contact1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LS-11D-CC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • End switch
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP65

Output electronic

Switching function

Slow-action switch

Rated operation current Ie at DC-13, 230 V

0.3A

Type of control element

Plunger

Construction type housing

Cuboid

Forced opening

Type of interface for safety communication

None

Type of interface

None

Rated operation current Ie at AC-15, 230 V

6A

Suitable for safety functions

With status indication

Material housing

Plastic

Explosion safety category for dust

None

Rated operation current Ie at AC-15, 125 V

6A

Number of safety auxiliary contacts

0

Explosion safety category for gas

None

Type of electric connection

Cable entry metrical

Coating housing

Other

Width sensor

31mm

Rated operation current Ie at DC-13, 24 V

3A

Rated operation current Ie at AC-15, 24 V

6A

Rated operation current Ie at DC-13, 125 V

0.8A

Alignment of the control element

Roller cam straight

Ambient temperature during operating

-40 .. 70°C

Height of sensor

61mm

Length of sensor

33.5mm

Diameter sensor

0mm

Number of contacts as normally closed contact

1

Switching function latching

Number of contacts as change-over contact

0

Degree of protection (NEMA)

Other

Number of contacts as normally open contact

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.