Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting160 - 200A
Rated permanent current Iu200A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Device constructionBuilt-in device plug-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of poles4
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release6 - 10A
With integrated under voltage releaseNo
Type of control elementRocker lever
Complete device with protection unitYes
Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC2-4-A200/125-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

160 .. 200A

Rated permanent current Iu

200A

Rated voltage

690 .. 690V

Integrated earth fault protection

Device construction

Built-in device plug-in technique

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

6 .. 10A

With integrated under voltage release

Type of control element

Rocker lever

Complete device with protection unit

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

With switched-off indicator

Motor drive optional

DIN rail (top hat rail) mounting optional