Technical specifications

Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Overload release current setting200 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitFrame clamp
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Type of control elementRocker lever
Motor drive optionalYes
Adjustment range undelayed short-circuit release1500 - 2500A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
With switched-off indicatorNo
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC2-A250-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Overload release current setting

200 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Frame clamp

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Type of control element

Rocker lever

Motor drive optional

Adjustment range undelayed short-circuit release

1500 .. 2500A

Position of connection for main current circuit

Front side

Integrated earth fault protection

With switched-off indicator

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Complete device with protection unit