Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Rated permanent current Iu500A
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting400 - 500A
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Number of poles4
With integrated under voltage releaseNo
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release3000 - 5000A
Motor drive optionalYes
Type of control elementRocker lever
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC3-4-A500/320

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated permanent current Iu

500A

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

400 .. 500A

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of poles

4

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

3000 .. 5000A

Motor drive optional

Type of control element

Rocker lever

Degree of protection (IP)

IP20