Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu320A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Overload release current setting250 - 320A
Adjustment range undelayed short-circuit release1920 - 3200A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of poles3
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
With switched-off indicatorNo
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Type of control elementRocker lever
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC3-A320-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

320A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Overload release current setting

250 .. 320A

Adjustment range undelayed short-circuit release

1920 .. 3200A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of poles

3

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive integrated

Motor drive optional

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Related products