Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device constructionBuilt-in device plug-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Rated voltage690 - 690V
Overload release current setting250 - 320A
Type of electrical connection of main circuitScrew connection
Rated permanent current Iu320A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1500 - 3200A
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
Motor drive optionalYes
With switched-off indicatorNo
Degree of protection (IP)IP20
Number of poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC3-A320-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device construction

Built-in device plug-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Rated voltage

690 .. 690V

Overload release current setting

250 .. 320A

Type of electrical connection of main circuit

Screw connection

Rated permanent current Iu

320A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1500 .. 3200A

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Motor drive integrated

Motor drive optional

With switched-off indicator

Degree of protection (IP)

IP20

Number of poles

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.