Technical specifications

Rated permanent current Iu250A
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of poles3
Type of control elementRocker lever
Complete device with protection unitYes
Degree of protection (IP)IP20
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release8 - 14A
Motor drive optionalYes
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Overload release current setting0 - 0A
Integrated earth fault protectionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMC3-S250

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of poles

3

Type of control element

Rocker lever

Complete device with protection unit

Degree of protection (IP)

IP20

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

8 .. 14A

Motor drive optional

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Overload release current setting

0 .. 0A