Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage400 - 400V
Adjustment range undelayed short-circuit release1500 - 2500A
Overload release current setting200 - 250A
Rated permanent current Iu250A
Adjustment range short-term delayed short-circuit release0 - 0A
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Type of control elementRocker lever
Motor drive integratedNo
Complete device with protection unitYes
Number of poles3
Motor drive optionalYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A250-FIA30-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

400 .. 400V

Adjustment range undelayed short-circuit release

1500 .. 2500A

Overload release current setting

200 .. 250A

Rated permanent current Iu

250A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

With integrated under voltage release

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Motor drive integrated

Complete device with protection unit

Number of poles

3

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Related products